Price :
$29.97You Save :
$33.02 (52%)Item Description
Amazon.com Product Description
The Kidde 0919-9999 Battery-Operated Wireless Smoke
Alarm allows for the simple installation of an interconnected smoke
alarm system without the high cost and hassle of rewiring your home. The alarms are wirelessly linked so that when one alarm is triggered, all alarms will sound. This alarm can also be placed in a detached workshop or shed and linked into the home's interconnected technique.
Specialists suggest interconnected alarms, simply because when one sounds, they all sound, delivering an early warning against fire by dramatically raising your ability to hear an alarm anyplace in your property, regardless of exactly where the fire begins. Newer homes are required by code to have interconnected alarms. Wireless technologies now enables any house to have an interconnected system.
This alarm uses ionization sensing engineering. Ionization sensing alarms may detect invisible fire particles (linked with flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms might possibly detect visible particles (related with smoldering fires) sooner than ionization alarms. Kidde strongly recommends that both ionization and photoelectric smoke alarms be installed to help insure maximum detection of the various types of fire that can happen within the household.
Opt for the Ideal Wireless Alarms for Your HomeKidde provides two wireless item alternatives: a Battery Powered Smoke Alarm, and an AC Powered Smoke Alarm. These items enable you to customize your program based on your specific needs. Read below to see which Kidde wireless smoke alarms are top for your residence.
Why Wireless?
- When a single alarm sounds they all do
- Capability to interconnect without the need of wires
- Install in minutes, anywhere in the household
- Much less expense, and much less hassle than re-wiring
An interconnected system provides more warnings in extra locations in case of smoke or fire in your home.
The Kidde Wireless Program alarms have a hush button to silence nuisance alarms. .Receiving Began with Wireless Interconnect in Three Effortless Steps
Step 1 - Identify the sort of smoke alarms at the moment installed in your home.
1. Battery PoweredNo wires runs only on batteries.Most older houses have battery-powered smoke alarms. These alarms have no protruding wires and are battery powered.
two. HardwiredRuns on your home's electricity and may have battery backup. Only one alarm sounds when test button is pressed.If your dwelling was built in the final 20 years, you likely have hardwired smoke alarms. If only the alarm that you test sounds, then you do not have an interconnected system.
3. InterconnectedRuns on your home's electricity and may have battery backup. All alarms sound when 1 test button is pressed.Properties built in the last 15 years may very well have an interconnected smoke alarm method. If all alarms sound when you test, you have an interconnected technique.
Step two - Choose how several alarms you desire in your household.
The NFPA recommends at least 1 smoke alarm on each and every level of the home and in each and every sleeping area.
Step three - Based on your home's existing alarm set-up, choose which Kidde Wireless alarms to invest in.
1. If your property has only battery powered alarms: Obtain adequate Kidde Wireless Battery Powered Smoke Alarms (0919-9999) to replace all of your existing smoke alarms. You will also have the capacity to add Kidde Wireless Battery Powered Alarms in further rooms for expanded coverage.
two. If your residence has only hardwired smoke alarms: Obtain enough Kidde Wireless AC Powered Smoke Alarms (1279-9999) to replace all of your present smoke alarms. You will also have the capability to add Kidde Wireless Battery Powered Alarms in further rooms for expanded coverage.
three. If your property has interconnected smoke alarms: Purchase a single Kidde Wireless AC Powered Smoke Alarms to replace 1 existing smoke alarm. Kidde Wireless Battery Powered Alarms can then be installed in additional rooms.
Interconnectable for Improved SafetyFire and consumer experts recommend interconnected alarms for added protection. According to the National Fire Protection Association (NFPA), most Americans really feel they are more at threat of becoming a victim of a tornado than of a house fire. In fact the opposite is correct. Fires are significantly more frequent than any other disaster that strikes a household at residence, and can grow to be deadly in minutes.
You have on common much less than three minutes from the time you hear a smoke alarm to escape a fire. The sooner you hear an alarm, the sooner you can get out safely. Smoke alarms that link together so that when 1 goes off, they all go off, are known as interconnected alarms. These alarms produce much more warnings in much more areas, giving your family members extra time to escape a residence fire. Homes built right after 1993 are needed by building codes to have interconnected alarms that are wired into their electrical method.
Trademarked Hush Feature for ConvenienceBy pressing the Hush button, you can simply and safely silence nuisance alarms brought on by non-emergency circumstances, such as overcooked dinners.
This alarm's Intelligent Hush feature has the capability of temporarily desensitizing the alarm circuit for up to eight minutes. This function is to be employed only when a identified alarm situation, such as smoke from cooking, activates the alarm. The smoke alarm is desensitized by pushing the Test/Hush button on the smoke alarm cover. If the smoke is not as well dense, the alarm will silence instantly. The red LED will illuminate for 1.5 seconds each 8 seconds although in hush. This indicates that the alarm is in a temporarily desensitized situation. The smoke alarm will automatically reset after roughly eight minutes and sound the alarm if particles of combustion are nonetheless present. Intelligent Hush can be utilized repeatedly until the air has been cleared of the condition causing the alarm. Pushing the Test/Hush button on the alarm will end the hush period.
three-AA Batteries, Indicator LED, and Test FeatureBecause a smoke alarm only helps protect you if it is working, this unit attributes a red LED that flashes each 10 seconds to indicate that it is operating properly. For further peace of mind, the alarm also consists of a test/reset button that enables you to periodically test its circuitry and horn.
The alarm's three-AA batteries supply continuous protection against smoke and fire hazards, even in the course of power outages. The unit offers a low battery warning that problems a brief chirp each 30 to 40 seconds for at least seven days just before losing power, letting you know that it's time to transform the battery.
This alarm is UL listed, so you can be confident of its top quality, and it is backed by a 10-year restricted warranty that lasts the life of the alarm.
About Kidde: A UTC Fire Security Brand Renowned for international leadership in fire detection and suppression, Kidde gives options ranging from portable fire extinguishers to advanced industrial controls such as flame detection and explosion suppression systems.
Kidde is a UTC Fire Security brand, with a history that's wealthy with innovations, from the patent of the Chubb Detector Lock in 1818 to the development of the world's initial wireless networked smoke detectors in 2004.
What is in the BoxOne 0919-9999 smoke alarm with mounting bracket and mounting hardware, 3- AA batteries, a 10-year restricted warranty and a bilingual user's manual.
From the Manufacturer
There are only minutes to escape a property fire. The sooner you hear the smoke alarm, the sooner you can get out safely. Kidde interconnected Ionization smoke alarms present early warning against fire by linking together the smoke alarms in your home, dramatically growing your capability to hear an alarm anywhere, regardless of where the fire starts. The Kidde Wireless Smoke Alarm enables families to swiftly install an interconnected smoke alarm system all through their residence with no the mess of rewiring or expense of labor. Interconnected smoke alarms give an earlier warning to fire for the reason that they link together so that when a single alarm sounds, they all sound. This delivers much more warning in much more places, and provides families additional time to escape. This battery-powered alarm hyperlinks with other alarms and elements of the Kidde Wireless Technique to build a customized, advanced fire protection technique. It even can be placed in a detached workshop or shed and linked into the home's program. Install UL listed smoke alarms on every floor of your household, in hallways, inside bedrooms and outside of sleeping places. Replace smoke alarms just about every 10 years. Ionization sensing alarms may very well detect invisible fire particles, associated with speedy flaming fires sooner than Photoelectric alarms. Scientific studies show each types will correctly detect either kind of fire. For optimal protection, install each smoke alarm technologies in your property.